Electrochemical behavior of various implantation biomaterials in the presence of various simulated body fluids: An overview
DOI:
https://doi.org/10.5937/zasmat2103213MKeywords:
corrosion, Hank solution, alloy, artificial body fluidsAbstract
In Modern medicine, metals and alloys are being used as implants. The Corrosion behaviour of various biomaterials under artificial body fluids are being studied. Artificial biomaterials are being implanted inside the human body to replace bone, teeth, etc. Even organs are being medically substituted with different types of metals such as mild steel, carbon steel, Ni-Cr alloy, Fe-Cr alloy, 22 carat Gold,24 carat Gold Tin, etc. due to their biocompatibility. This is achieved by connecting these metals directly with body tissues. The metals tend to corrode when it gets in contact with human body fluids. The body fluids thereby come in direct contact with tissues and the tissues are in contact with the metal thus causing the metal to corrode. And hence the corrosion resistance studies such as polarisation, AC impedance, cyclic voltammetric studies, etc, are being conducted in a medium like artificial blood plasma, artificial urine, artificial salvia, artificial sweat, Hank solution, Ringer solution, etc. The different body fluids are examined in the presence of different implantation metals by electrochemical methods and protective films are formed which are analyzed by various surface analysis techniques such as AFM, FTIR-UV, SEM, etc. The research findings will thereby be very helpful to the medical field.References
Affi, J., Ihsan, F., Fajri, H., Gunawarman, P. (2019) Corrosion Behavior of New Type Titanium Alloy As Candidate for Dental Wires in Artificial Saliva on Fluctuating Temperatures.IOP Conference Series: Materials Science and Engineering, 547(1): 012022
https://doi.org/10.1088/1757-899X/547/1/012022
Agiladevi, S., Rajendran, S. (2019) Electrochemical studies on the corrosion behaviour of metals and alloys in simulated ringer 's solution.Rasayan Journal of Chemistry, 12(1): 22-31
https://doi.org/10.31788/RJC.2019.1215037
Agnes, B.V., Thangavelu, C., Rajendran, S., Al-Hashem, A. (2018) Corrosion resistance of SS18/8 alloy, SS316L alloy, Gold18 carat and Gold 22 carat in artificial saliva in the absence and presence of erythromycin tablet 500mg.Zaštita materijala, vol. 59, br. 2, str. 182-188
https://doi.org/10.5937/ZasMat1802182V
Ahmadian, Z., Danaee, I., Golozar, M.A. (2014) Effect of surface treatment on Corrosion Resistance of 304 Stainless Steel implants in Tyrode solution.Archives of Metallurgy and Materials, 59(1): 25-30
https://doi.org/10.2478/amm-2014-0004
Cheng, F.T., Lo, K.H., Man, H.C. (2006) An electrochemical study of the crevice corrosion resistance of NiTi in Hanks' solution.Journal of Alloys and Compounds, 437: 322-328
https://doi.org/10.1016/j.jallcom.2006.07.127
Elagli, K., Traisnel, M., Hildebrand, H.F. (1993) Electrochemical behaviour of titanium and dental alloys in artificial saliva.Electrochimica Acta, 38(13): 1769-1776
https://doi.org/10.1016/0013-4686(93)85075-A
El-Rabiei, M.M., Bahrawy, A., El-Feky, H.E., Negem, M., Safaa, M.M., Nady, H. (2020) The Effect of Ni Content on the Corrosion Resistance of Some Fe-Cr-Ni Alloys in Simulated Body Fluids in the Presence of H2O2 and Albumin.Journal of Bioand Tribo-Corrosion, 6: 52-61
https://doi.org/10.1007/s40735-020-00350-1
Erwansyah, E., Susilowati, C. (2019) The effect of snake fruit extract (Salaccazalacca) in inhibiting the release of Chromium (Cr) and Nickel (Ni) ion from stainless steel orthodontic wire to saliva.International Journal of Applied Pharmaceutics, 11(4): 3336-3344
Fekry, A.M., El-Sherif, R.M. (2009) Electrochemical corrosion behavior of magnesium and titanium alloys in simulated body fluid.Electrochimica Acta, 54: 7280-7285
https://doi.org/10.1016/j.electacta.2009.07.047
Gowri, S., Jaslin, L.B., Kanagamani, B., Kavitha, A., Maria, B.A., Muthunayaki, C., Pandeeswari, C., Maria, P.J., Umasankareswari, T., Jerald, M.L., Rajendran, S. (2020) Influence of Metformin Hydrochloride-250 mg (MFH) tablet on Corrosion Resistance of orthodontic wire made of NiCr alloy in Artificial Saliva.J Chem Sci Chem Engg, 1(1): 1-10
https://doi.org/10.47890/JCSCE/SRAJENDRAN/2020/10082111
John, M.S., Rajendran, S. (2013) Corrosion Behaviour of SS316L in Artificial Blood Plasma in Presence of Amoxicillin Portugaliae.Electrochimica Acta, 31(1): 33-40
https://doi.org/10.4152/pea.201301033
John, M.S., Rajendran, S. (2013) Corrosion behaviour of metals in artificial blood plasma in presence of glucose.Portugaliae Electrochimica Acta, 31(1): 33-40
https://doi.org/10.4152/pea.201301033
Joseph, Rathish R., Rajendran, S., Lydia Christy J., Shyamala Devi, B., Johnmary, S., Manivannan, M., Rajam, K., Rengan, P. (2010) Corrosion behaviour of metals in Artificial Sweat.Open Corrosion Journal, 3: 38-44
https://doi.org/10.2174/1876503301003010038
Kajzer, W., Krauze, A., Walke, W., Marciniak, J. (2006) Corrosion resistance of Cr-Ni-Mo steel in simulated body fluids.Journal of Achievements in Materials and Manufacturing Engineering, 18(1-2): 56-64
Kamiński, J., Małkiewicz, K., R, biś J., Wierzchoń, T. (2020) The effect of glow discharge nitriding on the corrosion resistance of stainless steel orthodontic arches in artificial saliva solution.Archives of Metallurgy and Materials, 65(1): 375-384
https://doi.org/10.24425/amm.2020.131740
Liang, C., Zheng, R., Huang, N., Wu, B. (2010) Electrochemical behaviour of Ti-Ni SMA and Co-Cr alloys in dynamic Tyrode's simulated body fluid.J Mater Sci Mater Med, 21: 1421-1426
https://doi.org/10.1007/s10856-010-4002-z
Liu, L., Qiu, C.L., Chen, Q., Zhang, S.M. (2006) Corrosion behavior of Zr-based bulk metallic glasses in different artificial body fluids.Journal of Alloys and Compounds, 425(1-2), 268-273
https://doi.org/10.1016/j.jallcom.2006.01.048
Lu, Ch., Zheng, Y., Zhong, Q. (2017) Corrosion of dental alloys in artificial saliva with Streptococcus mutans.PLoS ONE, 12(3): e0174440
https://doi.org/10.1371/journal.pone.0174440
Mary, A.C.C., Rajendran, S., Jeyasundari, J. (2017) Influence of Coffee on the corrosion resistance of SS 316L, Ni-Ti alloy and thermoactive alloy in artificial saliva.Eur. Chem. Bull, 6(6): 232-237
https://doi.org/10.17628/ecb.2017.6.232-237
Mary, C.C.A., Rajendran, S., Jeyasundari, J., Dorothy, R. (2017) Corrosion resistance of Ni-Ti alloy, SS18/8 alloy and thermoactive alloy in artificial saliva in the absence and presence of tea.Zaštita materijala, vol. 58, br. 4, str. 469-474
https://doi.org/10.5937/ZasMat1704469C
Mary, J.S., Rajendran, S. (2014) Corrosion behavior of Cu-Ni-Ti in artificial blood plasma in presence of cholesterol.Zaštita materijala, vol. 55, br. 3, str. 244-250
https://doi.org/10.5937/ZasMat1403244M
Mary John S., Puthlibai, G., Kathiravan, P., Mano, D.J., Selvam, A. (2021) Electrochemical behaviour of Ni-Ti (Super elastic) alloy in artificial saliva in the presence of Phexin.Materials today proceedings, 36(4): 878-882
https://doi.org/10.1016/j.matpr.2020.07.022
Musa-Trolić, I., Serdarević, N.L., Todorić, Z., Spalj, S., Otmačić-Ćurković, H. (2019) Corrosion of orthodontic archwires in artificial saliva in the presence of Lactobacillus reuteri.Surface and Coatings Technology, 370: 44-52
https://doi.org/10.1016/j.surfcoat.2019.04.081
Nagalakshmi, R., Rajendran, S., Sathiyabama, J., Pandiarajan, M., Lydia, C.J. (2013) Corrosion behaviour of metals in Artificial Urine in presence of Sodium Chloride.European Chemical Bulletin, 2(4): 150-153
Nagalakshmi, R., Sathiyabama, J., Basha Ameeth, I., Mary, J.S. (2017) Invitro Corrosion studies on Nickel Titanium Super elastic alloy in synthetic urine in presence of D-Glucose.International Journal of Materials Science, 12(2): 51-59
Nahusona, D.R., Koriston, P. (2019) The effectiveness of watermelon rind extract as corrosion inhibitor in stainless steel orthodontic wire.International Journal of Applied Pharmaceutics, 11(4): 2225-2233
Nikolova, M.P., Yankov, E.H. (2019) Corrosion Study of Ti5Al4V and Ti6Al4V in different Simulated Body fluids. in: da Silva L.F.M. [ed.] Materials Design and Applications: Advanced Structured Materials, Switzerland: Springer Nature Switzerland AG, II, 98
https://doi.org/10.1007/978-3-030-02257-0_4
Petrović-Mihajlović, M.B., Radovanović, M.B., Simonović, A.T., Tasić, Ž.Z., Antonijević, M.M. (2019) Evaluation of purine based compounds as the inhibitors of copper corrosion in simulated body fluid.Results in Physics, 14: 102357
https://doi.org/10.1016/j.rinp.2019.102357
Pohrelyuk, I.M., Tkachuk, O.V., Proskurnyak, R.V. (2012) Corrosion Behaviour of Ti-6Al-4V Alloy with Nitride Coatings in Simulated Body Fluids at 36°C and 40°C.ISRN Corrosion, ID 241830
https://doi.org/10.1016/j.corsci.2012.10.005
R.Nagalakshmi,, Rajendran, S., Sathiyabama, J. (2013) Corrosion Inhibitive Effect of Metal and alloy in artificial Urine in presence of Urea.International Journal of Advances in Engineering and Technology, 6(4): 1914-1921
Rajendran, S., Paulraj, J., Rengan, P., Jeyasundari, J., Manivannan, M. (2009) Corrosion behaviour of metals in artificial saliva in presence of spirulina powder.Journal of Dentistry and Oral Hygiene, 1(1): 001-008
Rajendran, S., Uma, V., Krishnaveni, A., Jeyasundari, J., Shyamaladevi, B., Manivannan, M. (2009) Corrosion behavior of metals in artificial saliva in presence of D-Glucose.Arabian Journal for Science and Engineering, 34(2C) 147-158
Saha, N., Basu, J., Sen, P., Majumdar, G. (2020) Electrochemical behaviour of martensitic stainless steel with blood.Materials Today: Proceedings, 26(2): 677-680
https://doi.org/10.1016/j.matpr.2019.12.364
Sharma, M., Ramesh, K.A.V., Singh, N., Adya, N., Saluja, B. (2008) Electrochemical Corrosion Behavior of Dental/Implant Alloys in Artificial Saliva.Journal of Materials Engineering and Performance, 17(5): 687-695
https://doi.org/10.1007/s11665-008-9198-4
Sharma, M.R., Mahato, N., Cho, M.H., Chaturvedi, T.P., Singh, M.M. (2019) Effect of fruit juices and chloride ions on the corrosion behavior of orthodontic archwire.Materials Technology, 34(1): 18-24
https://doi.org/10.1080/10667857.2018.1473992
Tsutsumi, Y., Takano, Y., Doi, H., Noda, K., Hanawa, T. (2007) Corrosion Behaviour of Zirconium based alloys in Simulated Body Fluids. in: Materials Science Forum, Switzerland: Trans Tech Publications, 561-565: 1489-1492
https://doi.org/10.4028/www.scientific.net/MSF.561-565.1489
Walke, W., Paszenda, Z., Ziêbowicz, A. (2007) Corrosion behaviour of Co-Cr-W-Ni alloy in diverse body fluids.International Scientific Journal, 28(5): 293-296
Yang, H., Yang, K., Zhang, B. (2006) Pitting Corrosion resistance of La added 316L stainless steel in simulated body fluids.Materials Letters, 61(4-5): 1154-1157
https://doi.org/10.1016/j.matlet.2006.06.071
Ziębowicz, B., Woźniak, A., Ziębowicz, A., Ziembińska-Buczyńska, A. (2019) Analysis of the surface geometry of the orthodontic archwire and their influence on the bacterial adhesion.Journal of Achievements in Materials and Manufacturing Engineering, 93(1-2): 32-40
Downloads
Published
Issue
Section
License
Copyright (c) 2021 CC BY 4.0 by Authors
This work is licensed under a Creative Commons Attribution 4.0 International License.